产品中心banner
GKF-600
产品名称 |
GKF-600-19 |
GKF-600-24 |
GKF-600-36 |
GKF-600-48 |
|||||
输出 |
直流电压 |
19V |
24V |
36V |
48V |
||||
额定输出电流 |
31.6A |
25A |
16.7A |
12.5A |
|||||
输出电流范围 注1 |
0~31.6A |
0~25A |
0~16.7A |
0~12.5A |
|||||
纹波与噪音注2 峰-峰值电压 |
0-70℃ |
150mV |
200mV |
150mV |
240mV |
||||
-20℃ |
300mV |
400mV |
240mV |
480mV |
|||||
输出电压调节范围 |
18.05~20.9V |
23.5~27.2V |
35.1~39.6V |
46.0~54.0V |
|||||
稳压精度 |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
|||||
电源电压调整率 |
±0.5% |
±0.5% |
±0.5% |
±0.2% |
|||||
负载调节率 |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|||||
输出启动时间 |
<1.5S (230Vac 输入满载), <2S (115Vac 输入, 满载) |
||||||||
输出保持时间 |
>10mS/ (230Vac输入, 满载) |
||||||||
温度系数 |
±0.05%/℃ |
||||||||
电压过冲 |
<5.0% |
||||||||
输入 |
输入电压范围 |
88Vac~264Vac |
|||||||
频率范围 |
47Hz--63Hz |
||||||||
功率因数(典型值) |
PF>0.98/115VAC PF>0.95/230VAC |
||||||||
效率( 典型值) |
88% |
90% |
91.5% |
92% |
|||||
输入电流(最大值) |
<7A |
||||||||
启动冲击电流(典型值) |
<30A@230Vac 电源冷机启动 |
||||||||
保护功能 |
过流保护 |
110%~135% 额定输出电流,恒流 |
|||||||
过温保护 |
95℃+10℃(检测MOS管温度);关机,温度降低到70℃以下可自恢复 |
||||||||
过压保护 |
110%~150% 额定输出电压,恒压 |
||||||||
短路保护 |
可长期短路,消除短路后可自动恢复 |
||||||||
工作环境 |
工作温度及湿度 |
-20℃~70℃; 20%~90%RH 不冷凝(详情请参考降额曲线图) |
|||||||
储存温度及湿度 |
-40℃~85℃; 10%~95%RH 不冷凝 |
||||||||
安全及电磁兼容标准 (注3) |
安全标准 |
GB4943/EN60950 |
|||||||
绝缘强度 |
输入-输出:3.0KVac; ≤10mA .输入-地:1.5KVac; ≤10mA. 输出-地:0.5KVac;≤10mA. |
||||||||
绝缘阻抗 |
≥100Mohms |
||||||||
泄漏电流 |
输入对地≤3.5mA/240VAC,输入-输出﹤0.25mA@264Vac |
||||||||
电磁干扰 |
EN55022(CISPR22)ClassB |
||||||||
谐波电流 |
EN61000-3-2,17625.1-2003 |
||||||||
电磁抗干扰性 |
EN61000-4-2,3,4,5,6,8,11;ENV50204,A级重工业标准 |
||||||||
其他 |
MTBF (MIL-HDBK-217F) |
More than 100,000Hrs (25℃, 满载) |
|||||||
尺寸(长*宽*高) |
170*120*83.5m(不含端子) |
||||||||
包装 |
1.5kg/台每箱6台 |
||||||||
冷却方式 |
自带风扇风冷 |
||||||||
注释 |
1. 如未特别说明,所有规格参数均在额定输入、额定负载、25℃环境温度选进行量测. 2. 纹波噪音测试方法:使用一条12#双绞线,同时终端要并联0.1uF和10uF的电容,在示波器20MHz带宽下进行量测. 3. 电源将会作为一个部件装在最终设备上,最终的设备仍需满足EMC 条件. |
底部二维码旁边的位置