产品名称 |
ABS-35-5 |
ABS-35-12 |
ABS-35-15 |
ABS-35-24 |
ABS-35-48 |
输出 |
直流电压 |
5V |
12V |
15V |
24V |
48V |
额定输出电流 |
6A |
3A |
2.4A |
1.5A |
0.76A |
输出电流范围 |
0~6A |
0~3A |
0~2.4A |
0~1.5A |
0~0.76A |
纹波噪声(注2) |
0~70℃ |
<50mV |
<80mV |
<80mV |
<120mV |
<180 mV |
峰-峰值电压 |
-25~0℃ |
<80mV |
<180mV |
<180mV |
<200mV |
<240mV |
输出电压调节范围 |
4.75V-5.5V |
11.4V-13.2V |
14.25V-16.5V |
22.8V-26.4V |
45.6V-52.8V |
稳压精度 |
±3.0% |
±3.0% |
±3.0% |
±3.0% |
±3.0% |
源调整率 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
负载调整率 |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
输出启动时间 |
<1S (230Vac 输入, 满载); |
输出保持时间 |
>20mS(230Vac 输入 满载); >10mS(120Vac 输入, 满载) |
温度系数 |
±0.03%/℃ |
电压过冲 |
<5.0% |
输入 |
输入电压范围 |
90Vac~264Vac |
频率范围 |
47Hz~63Hz |
效率 (230Vac, 典型值) |
78% |
81% |
85% |
85% |
86% |
输入电流(最大值) |
<1A |
启动冲击电流(典型值) |
<50A@264Vac 电源冷机启动 |
保护功能 |
过流保护 |
6.3A~9A |
3.15A~4.5A |
2.52A~3.6A |
1.58A~2.25A |
0.80A~1.14A |
恒功率 |
恒功率 |
恒功率 |
恒功率 |
恒功率 |
过压保护 |
5.5V~7.5V恒压 |
13.2V~18V恒压 |
16.5V~22.5V恒压 |
26.4V~36V恒压 |
52.8V~72V恒压 |
短路保护 |
可长期短路,消除短路后可自动恢复 |
工作环境 |
工作温度及湿度 |
-25℃~70℃; 20%~90%RH 不冷凝 (详情请参考降额曲线) |
储存温度及湿度. |
-40℃~85℃; 10%~95%RH 不冷凝 |
安全及电磁 |
安全标准 |
UL60950-1; EN60950-1 |
兼容标准 注3 |
绝缘强度 |
输入-输出:3.0KVac; ≤10mA .输入-地1.5KVac; ≤10mA.输出-地:0.5KVDC;≤10mA. |
绝缘阻抗 |
≥100M ohms |
泄漏电流 |
输入对地≤3.5mA;输入对输出≤0.25mA |
电磁干扰 |
Compliance to EN55022(CISPR22) ClassB |
谐波电流 |
Compliance to EN61000-3-2 |
电磁抗干扰性 |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,A级重工业标准 |
其他 |
MTBF (MIL-HDBK-217F) |
More than 200,000Hrs (25℃, 满载) |
尺寸 (长*宽*高) |
99×97×36mm |
冷却方式 |
自然风冷 |
注释 |
1. 如未特别说明,所有规格参数均在输入为230VAC、额定负载、25℃环境温度选进行量测 |
2. 纹波噪音测试方法: 使用一条12#双绞线,同时终端要并联0.1uF和10uF的电容,在示波器20MHz带宽下进行量测 |
3. 电源将会作为一个部件装在最终设备上,最终的设备仍需满足EMC条件. |